  1. Switch COM2 between RS232 and RS485 via jumpers J1C2 and J2C2. Jumper locations: Item No.27 and No.28 as shown in the figure below.

Qotom Mini PC

Item No.

Description

Jumper Label

27

RS232/RS485 Function switch jumper

J1C2

28

RS232/RS485 Function switch jumper

J2C2

RS232/RS485 Function switch jumper (J1C2)

Qotom Mini PC

Function select

Connecting pins

RS232

1‑3, 2‑4

RS485

3‑5, 4‑6

RS232/RS485 Function switch jumper (J2C2)

Qotom Mini PC

Function select

Connecting pins

RS232

1‑2

RS485

3‑4, 5‑6

Qotom Mini PC


Qotom Mini PC

  1. Software Configuration Press the DELETE key during power‑on to enter BIOS, then configure parameters as shown in the figure below.

Qotom Mini PC

Qotom Mini PC

Qotom Mini PC

  1. When Item No.27 and No.28 are set to RS485 mode, the pin definition of COM2 is shown as below:

Pin#

Signal

1

RS485‑

2

RS485+

5

GND

  1. Some RS485 devices require a 120‑ohm resistor connected in parallel between RS485+ and RS485‑ for proper operation. Depending on the connected device, it may be necessary to swap RS485+ and RS485‑.

  2. Solution 1 for serial port sequence disorder issue: A. Deploy a freshly installed operating system. GHOST‑based system images are not supported.

  3. Solution 2 for serial port sequence disorder issue: A. Manually assign COM port numbers from COM1 to COM‑6 sequentially in Windows Device Manager. B. Switch both the hardware jumpers and BIOS setting of COM2 to RS232 mode. C. Use a serial port test tool to map the logical COM number in OS to the physical COM port. D. After confirming the port mapping, re‑configure COM2 to RS485 mode for testing and normal use.